最淫荡的中国老骚屄视频,2020亚洲男人的天堂,色吊丝中文字幕在线观看,久久久无码中文字幕精品

Hotline:18857165617 Ms. Yang
Popular: Thermal desorption instrumentation ,Headspace sampler Purge and trapExtraction and distillationAtmospheric preconcentratorGas sampler and dynamic dilutor
News

Company dynamics

Home > News > Company dynamics

Main technical parameters of 95 bit automatic purging and trapping device

source:中儀宇盛   date:2022-04-24 11:25:30   click:
  


The 95 position full-automatic purging and trapping device is a new type of full-automatic purging and trapping device of Beijing Zhongyi Yusheng Technology Co., Ltd. It can be loaded into a 95 position sample bottle once fully loaded, and can be used with all domestic and imported GC and GCMS.

It is suitable for the analysis of volatile organic compounds in liquids and solids, and can also be used for derivative reaction treatment of samples. Liquid sample, sampling to U-tube for purging; For low content solid samples, use 40ml sample bottle to purge directly; For high content solid samples, purge after automatic methanol extraction and dilution.

Types of samples that can be tested: volatile organic compounds in water, wastewater, drinking water, seawater, blood, sediment, slime, soil, cosmetics, textiles, packaging, food, spices, etc.

Main technical parameters

1. Temperature control range of sample tube:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

2. Temperature control range of sample cup:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

3. Injection needle temperature control range:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

4. Temperature control range of GC transmission pipeline:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

5. Temperature control range of valve box:

5 ℃ to 250 ℃ above room temperature, set in increments of 1 ℃;

6. Temperature control range of U-shaped purging pipe:

5 ℃ to 80 ℃ above room temperature, set in increments of 1 ℃;

7. Temperature control range of water separator:

5 ℃ to 200 ℃ above room temperature, set in increments of 1 ℃;

8. Temperature control range of pure cleaning water:

5 ℃ to 90 ℃ above room temperature, set in increments of 1 ℃;

9. Trap temperature control range:

150 ℃ to 80 ℃, set in increments of 1 ℃;

10. Trap heating rate:

>2000 ℃ / min, no more than 5% internal overshoot (at 250 ℃);

11. High temperature cooling rate of trap:

Cooling from 250 ℃ to 40 ℃ within 70 seconds;

12. Sample injection accuracy:

RSD < 1% (n = 7), determined by gravimetric method;

13. Selection of sample dilution ratio:

Programmable dilution: 1:100, 1:50, 1:25, 1:10, 1:5, 1:2;

14. Gas flow control range:

5ml / min to 500ml / min;

15. Standard 95 position sample tray (40ml sample bottle) is equipped with sample tray cooling circulating water system to realize low-temperature cooling of sample bottle;


About Us
Company Profile
Appointment interview
corporate culture
Video Center
News
Company dynamics
Common problem
Product
PURGE AND TRAP SERIES
Headspace sampler
Thermal desorption
Gas generator
Consumables and accessories
Contact us
Add:Building 13,Zhongnan High-tech Electronic InformationIndustrial Park,Yanjiao Sanhe Langfang,Hebei,China.
EMAIL:info@bjzyyskj.com.cn
Tel:+86-010-61598028 18857165617 Ms. Yang
Fax:010-61598028-108
WeChat

Scan
Copyright ? 2018 Beijing Zhongyi Yusheng Technology Co., Ltd 京ICP備10046828號-2
大宁县| 札达县| 安远县| 确山县| 四川省| 东安县| 延吉市| 永年县| 永城市| 永昌县| 阿拉善右旗| 清河县| 临海市| 米泉市| 浦城县| 镇原县| 廊坊市| 盘山县| 五家渠市| 昌吉市| 常山县| 长阳| 道孚县| 措勤县| 高淳县| 安康市| 武川县| 蒲城县| 衡阳县| 哈巴河县| 开封市| 芦山县| 兴国县| 资兴市| 浠水县| 阿图什市| 清徐县| 江达县| 太保市| 那曲县| 山丹县|